選択 および 購入 の 風速計 プローブ
測定 範囲 of 流量 速度 from {{0}}} to 100m/s can be divided into three section: low speed: 0 to 5m/s; 中 速度: 5 to 40m/s; High speed: 40 to 100m/s. The thermal sensitive probe of the anmometer is used for * * measurement from 0 to 5m/s; The ロータリー プローブ of the 風速計 測定 a 流量 速度 of 5 to 40m/s with ideal results; By using a pitot tube, excellent results can be obtained in the high-speed range. An additional standard for selecting the flow rate probe of an 風速計 正しく is 温度, which is typally used by the thermal sensor of the the 風速計 at 温度 of およそ plus -70C. The ローター プローブ of the 特別に 設計された 風速計 can reach 350C. ピトー チューブ は 使用 用 温度 以上 プラス 350°C。
感熱 プローブ OF 風速計
The working principle of the thermal sensitive probe of the anemometer is based on the cold impact airflow taking away the heat on the thermal element. With the help of a regulating switch, the temperature is kept constant, and the regulating current is proportional to the flow rate. When using a thermosensitive probe in turbulence, airflow from all directions simultaneously impacts the thermal element, which can affect the accuracy of the measurement results. When measuring in turbulence, the reading of the flow velocity sensor of the thermal anemometer is often higher than that of the rotary probe. The above phenomena can be observed during pipeline measurement. According to different designs for managing pipeline turbulence, it can even occur at low speeds. Therefore, the anemometer measurement process should be carried out on the straight section of the pipeline. The starting point of the straight section should be at least 10 times before the measurement point × D (D=pipeline diameter, in CM); The endpoint should be at least 4 after the measurement point × Location D. The fluid cross-section must not have any obstruction. (edges, overhangs, objects, etc.)
位置決め の 風速計 入力 空気 流量
正しい 調整 位置 の 回転 プローブ の 風速計 は それ その 気流 方向 は 平行 へ 回転 軸 いつ プローブ は 穏やかに 回転 イン その 気流, the 読み取り 意志 変化 それに応じて いつ その 読み取り 到達 最大 値 of *, it 示す それ the プローブ is in the the 正しい 測定 位置。 When 測定 in a pipeline, the distance from the starting point of the straight part of the pipeline to the measurement point should be greater than 0XD, and the influence of turbulence on the thermal sensitive probe and pitot tube of the anmometer is 相対的 小さい。
測定 of 気流 速度 in パイプライン 使用 an 風速計
練習 持っている 証明された それ 16mm プローブ の 風速計 持っている a 広い 範囲 の アプリケーション. その サイズ 保証 良い 透過性 そして できる 耐える 流量 レート アップ に 60m/s. The 測定 of 気流 速度 in パイプライン is one of the 実現可能 測定 メソッド, および the 間接 測定 規制 (グリッド 測定 方法) is 適用可能 to 空気 測定。