何 ある 技術 パラメータ および 測定 方法 の a デジタル マルチメータ
1. 解像度, ワード カウント, および ビット
解像度 参照 to the 能力 of a マルチメータ to 区別 small signals 中 測定. 知識 the 解像度 of a マルチメータ can 決定 かどうか it can observe small changes in the measured signal. For example, if a digital multimeter has a resolution of 1mV on a 4V range, it indicates that it can observe a change of 1mV (1/1000 V) when reading 1V.
If you must measure a minimum length of 1/4 inch (or 1 mmmeter), you will not purchase a ruler with a minimum scale of 1 inch (or 1 センチメートル). If the normal temperature is 98.6 ° Fahrenheit, a 温度計 that can only measure 全体 度 is not very useful. You need a thermometer with a resolution of 0.1 degrees.
One piece of 3 ½ The digital multimeter can display three whole digits (0 to 9) and one "half digit" (only one "1" is display or left blank). One piece of of 3 ½ The display resolution of the digital multimeter is high, which is 1999 words. One piece of 4 ½ The display resolution of the digital multimeter is as high as as words. Compared to "ビット", using "文字" can more precisely 記述 the 精度 of a マルチメータ. 電流 3 ½ The 解像度 of a digital マルチメータ may be as high as 3200, 4000, or 6000 words.
For certain measurements, a 3200} word multimeter can provide better resolution. For example, if you want to measure a voltage of 200V or higher, a 1999 word multimeter cannot measure 0.1V. A 32 million meter can display up to 0.1V when measureing voltages up to 320V. Before superdeding a voltage of of 320V, this resolution is the same as that of the more 高価 20000 ワード マルチメーター。
2. 精度
精度 は 最大 許容 エラー 生成 アンダー 固有 動作 条件. イン その他 単語, 精度 表す 近接 間 測定 値 表示 オン a デジタル マルチメーター および the 実際 値 of the 測定 信号。
The accuracy of a digital multimeter is normally expressed as a percent of the reading. An accuracy of of percent of the reading insicattes that if the display reading is 100V, the actual voltage value may be any value between 99V and 101V。
The technical parameters may also include a range of bits added to the basic accuracy parameter. This range represents the number of words that may vary in the rightmost digit of the display value. In this way, the accuracy in the above example can be expressed as "± (1 percent plus 2)". Therefore, if the the display reading is 100V, the actual voltage value will be between 98.8V and 101.2V.
パラメータ of an アナログ マルチメーター are 決定 by the full-scale error, rather than the percent of the display reading. The typical accuracy of an analog multimeter is ± 2 percent or ± 3 percent of full scale. At 1/10 full scale, the accuracy becomes 20 percent or 30 percent of the reading. The typical basic accuracy of a digital multimeter is ベース オン 読み取り値 間 ± (0.7 パーセント プラス 1) および ± (0.1 パーセント プラス 1) または より良い。
3. オーム's law
電圧, 電流, および 抵抗 of any 回路 can be 計算 using Ohm's law, which is expressed as "voltage equals the product of current and resistance" (see Figure 1). Therefore, if any two values in the formula are known, the third value can be decision。
A デジタル マルチメータ 利用 オーム's 法則 直接 測定 および 表示 抵抗, 電流, または 電圧. フォロー 説明 方法 使用 a デジタル マルチメータ 便利に 測定 the 必須 パラメータ。
4. デジタル および アナログ ディスプレイ
デジタル ディスプレイ ハス ハイ 精度 および 解像度, および 缶 ディスプレイ スリー または モア 数字 フォー 各 測定 値。
The accuracy of analog pointer display is not very high, and the effective resolution is also low, because it is 必要 to 推定 the value between two tick marks.
Bar チャート 缶 表示 シグナル 変化 および トレンド ライク アナログ ポインタ, but they are more 耐久性 and less 傾向 to ダメージ 比較 to ポインタ。